Product data sheet
Valve
B2706-0406-4248-9E,
November 24, 2024
Seat Valve electrically force-controlled
Series E2702-B2706/04
Valve B2706/0406/4248-9E DC

Solenoid valve for gases and solid-free liquids. The seal at the valve seat is made by a rubber diaphragm. Force-operated solenoid valves can be used where direct-acting valves are required. The valves operate from 0 bar pressure difference and combine the advantages of servo- and direct-acting valves. An unusually large variety of options make the 27 series with flange connection the specialist 'par excellence'.

For more information follow this link:
Valve B2706/0406/4248-9E DC
Link Icon
Datasheet explicit
VersionB
Type of valve27Seat Valve electrically force-controlled
Connection type, valve seat06DN50 50mm
Kv-value (Δp = 1 bar H₂O)29.4 m³/h
Housing04EN-GJL250 grey cast
Sealing06EPDM
Voltage type4DC
Solenoid power2430W
Protection class8Ex protection
Valve option9Enormally closed + Magnetic sensor inductive NAMUR, Turck
System pressure0 - 6 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, DC
Temperature Mediumfrom -10 °C to 60 °C
Temperature Environmentfrom -10 °C to 60 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Solenoid .248 Steel K05924XX | terminal box M16x1,5 | 100%ED | Cable clamping range 6.5 - 9.5mm | Duty cycle 100% | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Gas: Ex II 2G Ex e mb IIC T4 Gb | Staub:Ex II 2D Ex mb tb IIIC T130°C Db |
Valve option9Enormally closed + Magnetic sensor inductive NAMUR, Turck
DescriptionValve opens with continuous voltage | Magnetic field sensor | Turck BIM-PST-Y1X Ex Zone 1, intrinsically safe | place of install.: top | Valve position: OPEN and CLOSE | Order isolating switch amplifier separately
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818071; Country of origin Germany; ECCN (US): N; AL: N