Seat Valve electrically force-controlled pneum. force pilot
Series E2601/08.. - D2606/08..
Valve D2604/0804/7005-EN
Externally- and force pilot operated Valve. Valve closed by spring force in rest position - NC. When the actuator (cylinder) is pressurised the piston (spindle) is lifted of the pilot and main orifice and the valve will open directly or servo assisted by the pressure differential (delta p) of the flow medium. A pressure differential (delta p) is not required for the operation. Further functions like NO - by spring force in rest position or double acting actuators are also available.
For more information follow this link:
Valve D2604/0804/7005-EN
Datasheet explicit
Datasheet universal
datasheet 26-08
Instructions
Manual - Valves electropneumatic (DE/EN)
Version | D | |
Type of valve | 26 | Seat Valve electrically force-controlled pneum. force pilot |
Connection type, valve seat | 04 | DN32 32mm |
Kv-value (Δp = 1 bar H₂O) | 18 m³/h | |
Housing | 08 | AISI 316 Ti - 1.4571(81) |
Sealing | 04 | PTFE |
Function | 7 | CLOSED with spring |
Design | 0 | straight seat, actuator brass |
Actuator size | 05 | ⌀50 |
Actuator volume | 60 cm³ | |
Valve option | EN | Sensor inductive, 1-fold |
System pressure | 0 - 16 bar (the max. operating pressure requires a control pressure of min. 6 bar) | |
Control pressure | 4 - 10 bar | |
Temperature Medium | from -40 °C to 200 °C | |
Temperature Environment | from -10 °C to 60 °C | |
Mounting position | in any position | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve |
Not applicable
Valve option | EN | Sensor inductive, 1-fold |
Description | Inductive sensor for position indication | BJ standard, round M12x1.5, in the bracket, requires customer information whether OPEN or CLOSED | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Customs export | Customs tariff number 84812090; Country of origin Germany; ECCN (US): N; AL: N |