Product data sheet
Valve
D2605-0504-7005-EN,
November 18, 2024
Seat Valve electrically force-controlled
Series D2601/05.. - D2609/05..
Valve D2605/0504/7005-EN

Externally- and force pilot operated Valve. Valve closed by spring force in rest position - NC. When the actuator (cylinder) is pressurised the piston (spindle) is lifted of the pilot and main orifice and the valve will open directly or servo assisted by the pressure differential (delta p) of the flow medium. A pressure differential (delta p) is not required for the operation. Further functions like NO - by spring force in rest position or double acting actuators are also available.

For more information follow this link:
Valve D2605/0504/7005-EN
Link Icon
Datasheet explicit
VersionD
Type of valve26Seat Valve electrically force-controlled
Connection type, valve seat05DN40 40mm
Kv-value (Δp = 1 bar H₂O)26 m³/h
Housing05EN-GP240GH cast steel
Sealing04PTFE
Function7CLOSED with spring
Design0straight seat, actuator brass
Actuator size05⌀50
Actuator volume60 cm³
Valve optionENSensor inductive, 1-fold
System pressure0 - 16 bar (the max. operating pressure requires a control pressure of min. 6 bar)
Control pressure4 - 10 bar
Temperature Mediumfrom -40 °C to 200 °C
Temperature Environmentfrom -10 °C to 60 °C
Mounting positionin any position
Specific use caseClosed system (includes open system)
scope of delivery1 valve
Not applicable
Valve optionENSensor inductive, 1-fold
DescriptionInductive sensor for position indication | BJ standard, round M12x1.5, in the bracket, requires customer information whether OPEN or CLOSED
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84812090; Country of origin Germany; ECCN (US): N; AL: N