Product data sheet
Valve
B9125-1315-4248-A9,
December 5, 2024
Seat Valve electrically force-controlled
Series B9123-B9128/1315 CRYO
Valve B9125/1315/4248-A9 DC

2/2-way stainless steel solenoid valve in cryogenic design for liquefied gases -196°C (LN2 nitrogen, LCO2 carbon dioxide). Due to the spindle extension, the valve body can be very well insulated or installed in a vacuum insulated coolbox. Since the solenoid is sufficiently removed from the cold source, the heat input is considered to be negligible. In addition, this valve design can be used with EEx magnets for explosion protection Zone I.

For more information follow this link:
Valve B9125/1315/4248-A9 DC
Link Icon
Datasheet explicit
VersionB
Type of valve91Seat Valve electrically force-controlled
Connection type, valve seat25G1 25mm
Kv-value (Δp = 1 bar H₂O)11 m³/h
Housing13AISI 316L - 1.4404
Sealing15PCTFE
Voltage type4DC
Solenoid power2430W
Protection class8Ex protection
Valve optionA9normally closed + Distance unit + Welded ends ISO 4200 (G-thread not applicable) + free of Oil/grease + dry
System pressure0 - 35 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, DC
Temperature Mediumfrom -196 °C to 60 °C
Temperature Environmentfrom -20 °C to 60 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Solenoid .248 Steel K05924XX | terminal box M16x1,5 | 100%ED | Cable clamping range 6.5 - 9.5mm | Duty cycle 100% | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Gas: Ex II 2G Ex e mb IIC T4 Gb | Staub:Ex II 2D Ex mb tb IIIC T130°C Db |
Valve optionA9normally closed + Distance unit + Welded ends ISO 4200 (G-thread not applicable) + free of Oil/grease + dry
DescriptionValve opens with continuous voltage | Distance unit between valve body and actuator | Innerparts dry and specially cleaned
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N