Series A554E-A554L 1015

Solenoid valve with small valve seat DN 0.5mm to max. DN 1.2 mm for high internal pressures. The max. possible pressure depends on the nominal width! The valve is closed in the rest position by spring force (NC). The energised solenoid pulls the solenoid armature against the force of the spring to the counter core. The valve opens. Valves of this type do not require differential pressure. The valve only seals and can be shut off in the direction of the arrow. Due to the small seat nozzles, it is recommended to install a fine filter 0.04mm directly upstream of the valve.
This series includes: 30 Products
Show all products
Technical informations
Connections
G1/4
Pressure
0 bar up to 500 bar
Temperature
-40 °C up to 80 °C
Type of Control
electr. direct
Housing materials
CW617N brass
Sealing
PTFE
Media
Air, Nitrogen Gas N2, CO2 carbon dioxide gas
All variants
Not the right product?
Use our filter and search function at the top of the page.