Product data sheet
Valve
A554H-1004-3012-S-6H,
September 16, 2024
Seat Valve electr. direct
Series A554E-A554L 1015
Valve A554H/1004/3012-S-6H AC

Solenoid valve with small valve seat DN 0.5mm to max. DN 1.2 mm for high internal pressures. The max. possible pressure depends on the nominal width! The valve is closed in the rest position by spring force (NC). The energised solenoid pulls the solenoid armature against the force of the spring to the counter core. The valve opens. Valves of this type do not require differential pressure. The valve only seals and can be shut off in the direction of the arrow. Due to the small seat nozzles, it is recommended to install a fine filter 0.04mm directly upstream of the valve.

For more information follow this link:
Valve A554H/1004/3012-S-6H AC
Link Icon
Datasheet explicit
VersionA
Type of valve55Seat Valve electr. direct
Connection type, valve seat4HG1/4 0.8mm
Kv-value (Δp = 1 bar H₂O)0.025 m³/h
Housing10CW617N brass
Sealing04PTFE
Voltage type3AC
Solenoid power0118,5W/24VA
Protection class2IP65
Valve optionS-6Hnormally closed + System .032/.012 > 90 bar + End position detection sensor
System pressure0 - 250 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC
Temperature Mediumfrom -40 °C to 90 °C
Temperature Environmentfrom -40 °C to 40 °C
Mounting positionActuator upright (preferred) or horizontal
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Connector w. rectifier & VDR EN 175301-803 A | IP65 when installed | Connectable cables Ø 4.5-11mm max.1.5mm² | 1x DC-solenoid .012
Valve optionS-6Hnormally closed + System .032/.012 > 90 bar + End position detection sensor
DescriptionValve opens with continuous voltage | S = Identification for high pressure. | Sensor B0044.000420 on solenoid system | Sensor cable M12 3m, LED B0040.000204 | Valve position: OPEN
REACH-RoHS conformityREACH Yes | RoHS Yes
Net weight1.05 kg
Customs exportCustoms tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N