Product data sheet
Valve
A3706-0504-T242-NW-B0,
December 19, 2024
Seat Valve electrically force-controlled
Series A3701-A3706/0504 TH
Valve A3706/0504/.242-NW-B0 AC, DC

The solenoid valve Type 37-TH is used for high temperatures of up to + 180°C. This valve is suitable for hot water and steam applications in the plant and mechanical engineering. The standard valve is non energized closed - NC. A non energized open -NO design can also be supplied. Temperatureresisting limit switches for both positions, i.e. OPEN and CLOSED can be added on request.

For more information follow this link:
Valve A3706/0504/.242-NW-B0 AC, DC
Link Icon
Datasheet explicit
VersionA
Type of valve37Seat Valve electrically force-controlled
Connection type, valve seat06DN50 50mm
Kv-value (Δp = 1 bar H₂O)42 m³/h
Housing05EN-GP240GH cast steel
Sealing04PTFE
Voltage type--To be specified later
Solenoid power2426W
Protection class2IP65
Valve optionNW-B0normally open + Temperature design + Magnetic switch 2-fold OPEN and CLOSE inductive 3-wire N/O contact PNP
System pressure0 - 6 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -20 °C to 180 °C
Temperature Environmentfrom -20 °C to 40 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T242 KT05124XX Steel | Terminal box M16x1,5 | 100%ED | Cable clamping range 5 - 10mm | Valve MatchCode G0xx.xxxxxx.0xx.0R1.0xx | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx |
Valve optionNW-B0normally open + Temperature design + Magnetic switch 2-fold OPEN and CLOSE inductive 3-wire N/O contact PNP
DescriptionValve closes with continous voltage | Turck BIM-PST-AP6X_46240 | fixed sensor cable, 2 m, 3-pole | place of install.: top | Valve position: OPEN and CLOSE
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818071; Country of origin Germany; ECCN (US): N; AL: N