Seat Valve electrically force-controlled
Series A3521-A3528/1004 DT
Valve A3522/1004/.322-QD AC, DC
Solenoid valve type 35-DT for high operating temperatures up to +230°C, seat sealing PTFE. Exceeding the temperature limit +200°C is achieved by additional measures. As the solenoid systems can be continuously energised (100% ED), an extension between valve cover and solenoid coil is necessary. The valve is designed without glands so that a high external tightness is possible.
For more information follow this link:
Valve A3522/1004/.322-QD AC, DC
Datasheet explicit
Version | A | |
Type of valve | 35 | Seat Valve electrically force-controlled |
Connection type, valve seat | 22 | G3/8 13mm |
Kv-value (Δp = 1 bar H₂O) | 2.8 m³/h | |
Housing | 10 | CW617N brass |
Sealing | 04 | PTFE |
Voltage type | -- | To be specified later |
Solenoid power | 32 | 21W |
Protection class | 2 | IP65 |
Valve option | QD | normally closed + Valve body with NPT thread + Distance unit |
System pressure | 0 - 10 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC | |
Temperature Medium | from -40 °C to 230 °C | |
Temperature Environment | from -40 °C to 40 °C | |
Mounting position | Pipeline horizontal, Actuator vertical up | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T322 Steel KT05132XX | Terminal box M16x1,5 | Cable clamping range 5 - 10mm | |
Valve option | QD | normally closed + Valve body with NPT thread + Distance unit |
Description | Valve opens with continuous voltage | Conical internal thread | Distance unit between valve body and actuator | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Customs export | Customs tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N |