Product data sheet
Valve
A6324-0815-7505-EO-BIM-UNT-AG41X,
April 19, 2025
Seat Valve pneum. direct
Series 63-0815-DT
Valve A6324/0815/7505-EO-BIM-UNT-AG41X
Type 63-DT with Peek sealings for temperature up to +250 °C have a directly acting and external medium operated type of control and need compressed air from min. 6 bar for switching. They have a simple and solid design and quick reaction times. High quality valves, very suitable for large series plants thanks to their variable design. In order to avoid water hammer effects, just select the option "valve closes against the media" . Optionally +300°C with metallic sealings.
For more information follow this link:
Valve A6324/0815/7505-EO-BIM-UNT-AG41X
Datasheet explicit
Datasheet universal
datasheet 63-DT
Instructions
Manual - Valves electropneumatic (DE/EN)
Others
Turck 2-wire BIM-UNT-AG41X/S1139/S1160
EC Declaration of Conformity
REACH Declaration
RoHS Declaration
Videos
Version | A | |
Type of valve | 63 | Seat Valve pneum. direct |
Connection type, valve seat | 24 | G3/4 18mm |
Kv-value (Δp = 1 bar H₂O) | 6.5 m³/h | |
Housing | 08 | AISI 316 - 1.4408 |
Sealing | 15 | PEEK-HT |
Function | 7 | CLOSED with spring |
Design | 5 | Actuator nickle plated |
Actuator size | 05 | ⌀50 |
Actuator volume | 60 cm³ | |
Valve option | EO-BIM-UNT-AG41X | Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact |
Pressure rating | PN40 | |
System pressure | 0 - 20 bar (the max. operating pressure requires a control pressure of min. 6 bar) | |
Control pressure | 6 - 8 bar | |
Temperature Medium | from -40 °C to 250 °C | |
Temperature Environment | from -10 °C to 60 °C | |
Mounting position | in any position | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve |
Not applicable
Valve option | EO-BIM-UNT-AG41X | Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact |
Description | Magnetic field sensor | Turck BIM-UNT-AG41X/S1139/S1160 | Cable 2m, 2-wire (replaces reed contact RC27) | place of install.: top | Valve position: OPEN and CLOSE | |
Leakage rate | B - EN 12266 [Test medium air or nitrogen, 20°C room temperature] | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Customs export | Customs tariff number 84812090; Country of origin Germany; ECCN (US): N; AL: N |