Product data sheet
Valve
3-918-23-1004-R371-1E,
December 29, 2024
Coaxial Valve electr. direct
Series 3/918-R371
Valve 3/918-23/1004/.371-1E AC, DC

3/2-way direct operated coaxial solenoid valve also for highly viscous, lubricating media up to 64 bar. Change-over valves type 3/918 are preferably used where classical seat valves cannot be used due to the fluid properties. Valve with sealing made of FKM, optionally EPDM/PTFE can be used for an extended range of applications. A further argument in favour of this design is the ability to flow through and shut off in all directions.

For more information follow this link:
Valve 3/918-23/1004/.371-1E AC, DC
Link Icon
Datasheet explicit
Version3/918-
Type of valveCoaxial Valve electr. direct
Connection type, valve seat23G1/2 15mm
Kv-value (Δp = 1 bar H₂O)5.2 m³/h
Housing10CW617N brass
Sealing04PTFE
Voltage type--To be specified later
Solenoid power3750W
Protection class1IP65
Valve option1ESensor inductive, 1-fold + NC in rest pos. P-A
System pressure0 - 64 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -40 °C to 100 °C
Temperature Environmentfrom -40 °C to 50 °C
Mounting positionin any position
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 connector FormA EN175301-803/A | max. current 10A | 4x90°| IP65 when installed | connectable cables Ø 5-10 mm max.1.5mm² | 1 solenoid | 1x solenoid 50W, 100%ED 1 Connector w. rectifier & VDR EN 175301-803 A | IP65 when installed | Connectable cables Ø 4.5-11mm max.1.5mm² | 1x solenoid 55W, 100%ED
Valve option1ESensor inductive, 1-fold + NC in rest pos. P-A
DescriptionInductive sensor for position indication | Valve position: OPEN or CLOSE | Indicate when ordering | Note increase in length +25mm | Plug 2m cable 3-pole with LED | In opposite flow direction up to max. 16 bar closing
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCountry of origin Germany; ECCN (US): N; AL: N