Series 27-05-TM
Solenoid valve for gases and solid-free liquids. The seal at the valve seat is made by a rubber diaphragm. Force-operated solenoid valves can be used where direct-acting valves are required.
The valves operate from 0 bar pressure difference and combine the advantages of servo- and direct-acting valves. An unusually large variety of options make the 27 series with flange connection the specialist 'par excellence'.
Technical informations
Connections
DN15, DN20, DN25, DN32, DN40, DN50
Pressure
0 bar up to 16 bar
Temperature
-20 °C up to 140 °C
Type of Control
electrically force-controlled
Housing materials
EN-GP240GH cast steel
Sealing
FKM | EPDM
Media
Motor Oil, Mineral Oil, Bilge Water (water-oil mix), Water, Hot above 90°C H2O, Steam 110°C, Condensate
All Products
E2701/0502/R802-BT
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Free of brass and copper Temperature design
E2701/0502/R802-BT
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Free of brass and copper Temperature design
E2701/0502/R802-HG
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally open Temperature design Manual operation HN
E2701/0502/R802-HG
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally open Temperature design Manual operation HN
E2701/0502/R802-NT
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally open Temperature design
E2701/0502/R802-NT
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally open Temperature design
E2701/0502/R802-OU
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design Free of oil and grease
E2701/0502/R802-OU
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design Free of oil and grease
E2701/0502/R802-TB
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design Manual operation HA
E2701/0502/R802-TB
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design Manual operation HA
E2701/0502/R802-TM
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design
E2701/0502/R802-TM
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design
E2701/0502/T012-BT
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 10 bar
normally closed Free of brass and copper Temperature design
E2701/0502/T012-BT
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 10 bar
normally closed Free of brass and copper Temperature design
E2701/0502/T012-OU
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 10 bar
normally closed Temperature design Free of oil and grease
E2701/0502/T012-OU
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 10 bar
normally closed Temperature design Free of oil and grease
E2701/0502/T012-TB
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 10 bar
normally closed Temperature design Manual operation HA
E2701/0502/T012-TB
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 10 bar
normally closed Temperature design Manual operation HA
E2701/0502/T012-TM
DN15
EN-GP240GH cast steel
FKM
AC
IP65
0 - 10 bar
normally closed Temperature design
E2701/0502/T012-TM
DN15
EN-GP240GH cast steel
FKM
DC
IP65
0 - 10 bar
normally closed Temperature design
E2701/0506/R802-BT
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 16 bar
normally closed Free of brass and copper Temperature design
E2701/0506/R802-BT
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 16 bar
normally closed Free of brass and copper Temperature design
E2701/0506/R802-HG
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 16 bar
normally open Temperature design Manual operation HN
E2701/0506/R802-HG
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 16 bar
normally open Temperature design Manual operation HN
E2701/0506/R802-NT
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 16 bar
normally open Temperature design
E2701/0506/R802-NT
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 16 bar
normally open Temperature design
E2701/0506/R802-TB
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 16 bar
normally closed Temperature design Manual operation HA
E2701/0506/R802-TB
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 16 bar
normally closed Temperature design Manual operation HA
E2701/0506/R802-TM
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 16 bar
normally closed Temperature design
E2701/0506/R802-TM
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 16 bar
normally closed Temperature design
E2701/0506/T012-BT
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 10 bar
normally closed Free of brass and copper Temperature design
E2701/0506/T012-BT
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 10 bar
normally closed Free of brass and copper Temperature design
E2701/0506/T012-TB
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 10 bar
normally closed Temperature design Manual operation HA
E2701/0506/T012-TB
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 10 bar
normally closed Temperature design Manual operation HA
E2701/0506/T012-TM
DN15
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 10 bar
normally closed Temperature design
E2701/0506/T012-TM
DN15
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 10 bar
normally closed Temperature design
E2702/0502/R322-1P
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design Reed contact 2-wire RC27-S-M12-4P
E2702/0502/R322-1P
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design Reed contact 2-wire RC27-S-M12-4P
E2702/0502/R322-BT
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Free of brass and copper Temperature design
E2702/0502/R322-BT
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Free of brass and copper Temperature design
E2702/0502/R322-ML
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design Reinforced closing spring.
E2702/0502/R322-ML
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design Reinforced closing spring.
E2702/0502/R322-NT
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally open Temperature design
E2702/0502/R322-NT
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally open Temperature design
E2702/0502/R322-NT-EA
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally open Reed contact 2-wire RC27-S-M12-4P Temperature design
E2702/0502/R322-NT-EA
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally open Reed contact 2-wire RC27-S-M12-4P Temperature design
E2702/0502/R322-OU
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design Free of oil and grease
E2702/0502/R322-OU
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design Free of oil and grease
E2702/0502/R322-TB
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 16 bar
normally closed Temperature design Manual operation HA
E2702/0502/R322-TB
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 16 bar
normally closed Temperature design Manual operation HA
E2702/0502/R802-BT
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2702/0502/R802-BT
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2702/0502/R802-OU
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design Free of oil and grease
E2702/0502/R802-OU
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design Free of oil and grease
E2702/0502/R802-TB
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2702/0502/R802-TB
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2702/0502/R802-TM
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design
E2702/0502/R802-TM
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design
E2702/0502/R802-TM-KT
DN20
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2702/0502/R802-TM-KT
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2702/0502/T012-BT
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Free of brass and copper Temperature design
E2702/0502/T012-OU
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Temperature design Free of oil and grease
E2702/0502/T012-TB
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Temperature design Manual operation HA
E2702/0502/T012-TM
DN20
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Temperature design
E2702/0506/R802-BT
DN20
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2702/0506/R802-BT
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2702/0506/R802-TB
DN20
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2702/0506/R802-TB
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2702/0506/R802-TM
DN20
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Temperature design
E2702/0506/R802-TM
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Temperature design
E2702/0506/R802-TM-KT
DN20
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2702/0506/R802-TM-KT
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2702/0506/T012-BT
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 8 bar
normally closed Free of brass and copper Temperature design
E2702/0506/T012-TB
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 8 bar
normally closed Temperature design Manual operation HA
E2702/0506/T012-TM
DN20
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 8 bar
normally closed Temperature design
E2703/0502/R802-BT
DN25
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2703/0502/R802-BT
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2703/0502/R802-OU
DN25
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design Free of oil and grease
E2703/0502/R802-OU
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design Free of oil and grease
E2703/0502/R802-TB
DN25
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2703/0502/R802-TB
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2703/0502/R802-TM
DN25
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design
E2703/0502/R802-TM
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design
E2703/0502/R802-TM-KT
DN25
EN-GP240GH cast steel
FKM
DC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2703/0502/R802-TM-KT
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2703/0502/T012-BT
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Free of brass and copper Temperature design
E2703/0502/T012-OU
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Temperature design Free of oil and grease
E2703/0502/T012-TB
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Temperature design Manual operation HA
E2703/0502/T012-TM
DN25
EN-GP240GH cast steel
FKM
AC
IP65
0 - 8 bar
normally closed Temperature design
E2703/0506/R802-BT
DN25
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2703/0506/R802-BT
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Free of brass and copper Temperature design
E2703/0506/R802-TB
DN25
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2703/0506/R802-TB
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Temperature design Manual operation HA
E2703/0506/R802-TM
DN25
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Temperature design
E2703/0506/R802-TM
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Temperature design
E2703/0506/R802-TM-KT
DN25
EN-GP240GH cast steel
EPDM
DC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2703/0506/R802-TM-KT
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 12 bar
normally closed Temperature design Sealing with FDA-approval
E2703/0506/T012-BT
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 8 bar
normally closed Free of brass and copper Temperature design
E2703/0506/T012-TB
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 8 bar
normally closed Temperature design Manual operation HA
E2703/0506/T012-TM
DN25
EN-GP240GH cast steel
EPDM
AC
IP65
0 - 8 bar
normally closed Temperature design
Not the right product?
Use our filter and search function at the top of the page.