Product data sheet
Valve
D2606-0804-8008-EO,
November 24, 2024
Seat Valve electrically force-controlled pneum. force pilot
Series E2601/08.. - D2606/08..
Valve D2606/0804/8008-EO

Externally- and force pilot operated Valve. Valve closed by spring force in rest position - NC. When the actuator (cylinder) is pressurised the piston (spindle) is lifted of the pilot and main orifice and the valve will open directly or servo assisted by the pressure differential (delta p) of the flow medium. A pressure differential (delta p) is not required for the operation. Further functions like NO - by spring force in rest position or double acting actuators are also available.

For more information follow this link:
Valve D2606/0804/8008-EO
Link Icon
Datasheet explicit
VersionD
Type of valve26Seat Valve electrically force-controlled pneum. force pilot
Connection type, valve seat06DN50 50mm
Kv-value (Δp = 1 bar H₂O)38 m³/h
Housing08AISI 316 Ti - 1.4571(81)
Sealing04PTFE
Function8OPEN with spring
Design0straight seat, actuator aluminium
Actuator size08⌀80
Actuator volume260 cm³
Valve optionEOInductive sensor, double
System pressure0 - 40 bar (the max. operating pressure requires a control pressure of min. 6 bar)
Control pressure4 - 10 bar
Temperature Mediumfrom -40 °C to 200 °C
Temperature Environmentfrom -10 °C to 60 °C
Mounting positionin any position
Specific use caseClosed system (includes open system)
scope of delivery1 valve
Not applicable
Valve optionEOInductive sensor, double
DescriptionInductive sensor for position indication | BJ standard, round M12x1.5, in the bracket, OPEN / CLOSE
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84812090; Country of origin Germany; ECCN (US): N; AL: N