Product data sheet
Valve
E2407-0404-T272-TH-1U-2,
November 18, 2024
Seat Valve electrically force-controlled
Series E2407-E2409-04-TH
Valve E2407/0404/.272-TH-1U-2 AC, DC

The valve type 24-TH is a forced-operated 2/2-way valve for use in steam and hot water applications up to +180°C. The valve cover is made of red brass, the valve seat of stainless steel. This ensures a long service life even when used with aggressive steam. The valve is normally closed-NC as standard. The normally open -NO version is optionally available. Limit switch contacts for both valve positions OPEN and CLOSED can be fitted on request.

For more information follow this link:
Valve E2407/0404/.272-TH-1U-2 AC, DC
Link Icon
Datasheet explicit
VersionE
Type of valve24Seat Valve electrically force-controlled
Connection type, valve seat07DN65 65mm
Kv-value (Δp = 1 bar H₂O)63 m³/h
Housing04EN-GJL250 grey cast | EN-GJL250 grey cast
Sealing04PTFE
Voltage type--To be specified later
Solenoid power2760W
Protection class2IP65
Valve optionTH-1U-2normally closed + Temperature design + Magnetic sensor inductive 3-wire N/O contact PNP
System pressure0 - 16 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -10 °C to 180 °C
Temperature Environmentfrom -10 °C to 40 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T272 KT05127XX Steel | Terminal box M16x1,5 | Cable clamping range 5 - 10mm | Valve MatchCode G0xx.xxxxxx.0xx.0R1.0xx | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx |
Valve optionTH-1U-2normally closed + Temperature design + Magnetic sensor inductive 3-wire N/O contact PNP
DescriptionValve opens with continuous voltage | Magnetic field sensor | Turck BIM-PST-AP6X_46240 | place of install.: top | Signal: closed
REACH-RoHS conformityREACH Yes | RoHS Yes
Net weight30.4 kg
Customs exportCustoms tariff number 84818071; Country of origin Germany; ECCN (US): N; AL: N