Product data sheet
Valve
A3702-0804-R802-TA,
September 16, 2024
Seat Valve electrically force-controlled
Series A3701-A3706/0804 TH
Valve A3702/0804/.802-TA AC, DC

The solenoid valve Type 37-TH is used for high temperatures of up to + 180°C (-TH). This valve is suitable for hot water and steam applications in the plant and mechanical engineering. The standard valve is non energized closed - NC. A non energized open -NO design can also be supplied. Temperatureresisting limit switches for both positions, i.e. OPEN and CLOSED can be added on request.

For more information follow this link:
Valve A3702/0804/.802-TA AC, DC
Link Icon
Datasheet explicit
VersionA
Type of valve37Seat Valve electrically force-controlled
Connection type, valve seat02DN20 20mm
Kv-value (Δp = 1 bar H₂O)8.5 m³/h
Housing08AISI 316 Ti - 1.4571(81)
Sealing04PTFE
Voltage type--To be specified later
Solenoid power8018W
Protection class2IP65
Valve optionTAnormally closed + Temperature design + Manual operation HA
System pressure0 - 10 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -40 °C to 180 °C
Temperature Environmentfrom -40 °C to 40 °C
Mounting positionActuator vertical up (preferable), or horizontal
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Connector w. rectifier & VDR EN 175301-803 A | IP65 when installed | Connectable cables Ø 4.5-11mm max.1.5mm² | 1 Solenoid Steel R802 | rotatable 360° | Valve MatchCode G0xx.xxxxxx.0xx.002.0xx | 1 connector FormA EN175301-803/A | max. current 10A | 4x90°| IP65 when installed | connectable cables Ø 5-10 mm max.1.5mm² | Valve MatchCode G0xx.xxxxxx.0xx.009.0xx |
Valve optionTAnormally closed + Temperature design + Manual operation HA
DescriptionValve opens with continuous voltage | Hand wheel under the valve body
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N