Product data sheet
Valve
B3704-0504-T322-TH-1U-2,
November 3, 2024
Seat Valve electrically force-controlled
Series A3701-A3706/0504 TH
Valve B3704/0504/.322-TH-1U-2 AC, DC

The solenoid valve Type 37-TH is used for high temperatures of up to + 180°C. This valve is suitable for hot water and steam applications in the plant and mechanical engineering. The standard valve is non energized closed - NC. A non energized open -NO design can also be supplied. Temperatureresisting limit switches for both positions, i.e. OPEN and CLOSED can be added on request.

For more information follow this link:
Valve B3704/0504/.322-TH-1U-2 AC, DC
Link Icon
Datasheet explicit
VersionB
Type of valve37Seat Valve electrically force-controlled
Connection type, valve seat04DN32 32mm
Kv-value (Δp = 1 bar H₂O)24 m³/h
Housing05EN-GP240GH cast steel | EN-GP240GH cast steel
Sealing04PTFE
Voltage type--To be specified later
Solenoid power3221W
Protection class2IP65
Valve optionTH-1U-2normally closed + Temperature design + Magnetic sensor inductive 3-wire N/O contact PNP
System pressure0 - 6 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -20 °C to 180 °C
Temperature Environmentfrom -20 °C to 40 °C
Mounting positionPipeline horizontal, Actuator vertical up
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T322 Steel KT05132XX | Terminal box M16x1,5 | Cable clamping range 5 - 10mm | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx |
Valve optionTH-1U-2normally closed + Temperature design + Magnetic sensor inductive 3-wire N/O contact PNP
DescriptionValve opens with continuous voltage | Magnetic field sensor | Turck BIM-PST-AP6X_46240 | place of install.: top | Signal: closed
REACH-RoHS conformityREACH Yes | RoHS Yes
Net weight10.4 kg
Customs exportCustoms tariff number 84818071; Country of origin Germany; ECCN (US): N; AL: N