Product data sheet
Valve
A3524-1004-T242-TM-1U,
November 3, 2024
Seat Valve electrically force-controlled
Series A3521-A3525/1004 TH
Valve A3524/1004/.242-TM-1U AC, DC

The solenoid valve type 35-TH for high temperature applications up to +180°C, suitable for hot water and steam applications in plant and apparatus engineering. Like all our valves, the Type 35-TH is normally closed -NC as standard. The normally open -NO version is available at an extra charge.

For more information follow this link:
Valve A3524/1004/.242-TM-1U AC, DC
Link Icon
Datasheet explicit
VersionA
Type of valve35Seat Valve electrically force-controlled
Connection type, valve seat24G3/4 20mm
Kv-value (Δp = 1 bar H₂O)
Housing10CW617N brass | CW617N brass
Sealing04PTFE
Voltage type--To be specified later
Solenoid power2426W
Protection class2IP65
Valve optionTM-1Unormally closed + Temperature design + Reed contact 2-wire RC27-S
System pressure0 - 40 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -40 °C to 180 °C
Temperature Environmentfrom -40 °C to 40 °C
Mounting positionActuator upright (preferred) or horizontal
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T242 KT05124XX Steel | Terminal box M16x1,5 | 100%ED | Cable clamping range 5 - 10mm | Valve MatchCode G0xx.xxxxxx.0xx.0R1.0xx | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx |
Valve optionTM-1Unormally closed + Temperature design + Reed contact 2-wire RC27-S
DescriptionValve opens with continuous voltage | Reed contact | RC27-S Art. B0044.000389 | Contact type: normally open contact | place of install.: top / horizontal | Signal: closed | Connector DIN EN 43650 Form C Art. B0040.000097
REACH-RoHS conformityREACH Yes | RoHS Yes
Net weight3.2 kg
Switching time (at 6 bar gas)On: 120 ms | Off: 160 ms
Customs exportCustoms tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N