Seat Valve electrically force-controlled
Series A3521-A3525/1004 TH
Valve A3524/1004/.242-NW AC, DC
The solenoid valve type 35-TH for high temperature applications up to +180°C, suitable for hot water and steam applications in plant and apparatus engineering. Like all our valves, the Type 35-TH is normally closed -NC as standard. The normally open -NO version is available at an extra charge.
For more information follow this link:
Valve A3524/1004/.242-NW AC, DC
Datasheet explicit
Version | A | |
Type of valve | 35 | Seat Valve electrically force-controlled |
Connection type, valve seat | 24 | G3/4 20mm |
Kv-value (Δp = 1 bar H₂O) | ||
Housing | 10 | CW617N brass | CW617N brass |
Sealing | 04 | PTFE |
Voltage type | -- | To be specified later |
Solenoid power | 24 | 26W |
Protection class | 2 | IP65 |
Valve option | NW | normally open + Temperature design |
System pressure | 0 - 40 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC | |
Temperature Medium | from -40 °C to 180 °C | |
Temperature Environment | from -40 °C to 40 °C | |
Mounting position | Actuator upright (preferred) or horizontal | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T242 KT05124XX Steel | Terminal box M16x1,5 | 100%ED | Cable clamping range 5 - 10mm | Valve MatchCode G0xx.xxxxxx.0xx.0R1.0xx | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | |
Valve option | NW | normally open + Temperature design |
Description | Valve closes with continous voltage | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Net weight | 2.1 kg | |
Switching time (at 6 bar gas) | On: 120 ms | Off: 160 ms | |
Customs export | Customs tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N |