Series 40-10-TM
Solenoid valve for gases and solid-free liquids. The valve seat is sealed by a rubber diaphragm.
Benefit from the advantages of the 40 series with threaded connection if you ensure that there is a minimum pressure difference between the inlet and outlet. The specification of the min. pressure difference can be found in the data sheets and precedes the max. possible pressure difference.
Valve is sensor-ready, configurable with end position detection as option -6H or for retrofitting.
Technical informations
Connections
G1/4, G3/8, G1/2, G3/4, G1, G5/4, G6/4, G2
Pressure
0.3 bar up to 20 bar
Temperature
-30 °C up to 140 °C
Type of Control
Electrically servo-assistent
Housing materials
CW617N brass
Sealing
EPDM
Media
Water, Hot above 90°C H2O, Steam 110°C, Condensate, Air
All Products

B4026/1006/T012-NT
G5/4
CW617N brass
EPDM
0.5 - 10 bar
AC
IP65
normally open Temperature design

B4026/1006/T012-NT
G5/4
CW617N brass
EPDM
0.5 - 10 bar
DC
IP65
normally open Temperature design

B4026/1006/T012-TM
G5/4
CW617N brass
EPDM
0.5 - 16 bar
AC
IP65
normally closed Temperature design

B4026/1006/T012-TM
G5/4
CW617N brass
EPDM
0.5 - 16 bar
DC
IP65
normally closed Temperature design

B4026/1006/T012-TM-6H
G5/4
CW617N brass
EPDM
0.5 - 16 bar
DC
IP65
normally closed Temperature design End position detection sensor

B4027/1006/T012-NT
G6/4
CW617N brass
EPDM
0.5 - 10 bar
AC
IP65
normally open Temperature design

B4027/1006/T012-NT
G6/4
CW617N brass
EPDM
0.5 - 10 bar
DC
IP65
normally open Temperature design

B4027/1006/T012-TM
G6/4
CW617N brass
EPDM
0.5 - 16 bar
AC
IP65
normally closed Temperature design

B4027/1006/T012-TM
G6/4
CW617N brass
EPDM
0.5 - 16 bar
DC
IP65
normally closed Temperature design

B4027/1006/T012-TM-6H
G6/4
CW617N brass
EPDM
0.5 - 16 bar
DC
IP65
normally closed Temperature design End position detection sensor

B4028/1006/T012-NT
G2
CW617N brass
EPDM
0.5 - 10 bar
AC
IP65
normally open Temperature design

B4028/1006/T012-NT
G2
CW617N brass
EPDM
0.5 - 10 bar
DC
IP65
normally open Temperature design

B4028/1006/T012-TM
G2
CW617N brass
EPDM
0.5 - 16 bar
AC
IP65
normally closed Temperature design

B4028/1006/T012-TM
G2
CW617N brass
EPDM
0.5 - 16 bar
DC
IP65
normally closed Temperature design

B4028/1006/T012-TM-6H
G2
CW617N brass
EPDM
0.5 - 16 bar
DC
IP65
normally closed Temperature design End position detection sensor

D4021/1006/T012-NT
G1/4
CW617N brass
EPDM
0.3 - 16 bar
AC
IP65
normally open Temperature design

D4021/1006/T012-NT
G1/4
CW617N brass
EPDM
0.3 - 16 bar
DC
IP65
normally open Temperature design

D4021/1006/T012-TM
G1/4
CW617N brass
EPDM
0.3 - 20 bar
AC
IP65
normally closed Temperature design

D4021/1006/T012-TM
G1/4
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design

D4021/1006/T012-TM-6H
G1/4
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design End position detection sensor

D4022/1006/T012-NT
G3/8
CW617N brass
EPDM
0.3 - 16 bar
AC
IP65
normally open Temperature design

D4022/1006/T012-NT
G3/8
CW617N brass
EPDM
0.3 - 16 bar
DC
IP65
normally open Temperature design

D4022/1006/T012-TM
G3/8
CW617N brass
EPDM
0.3 - 20 bar
AC
IP65
normally closed Temperature design

D4022/1006/T012-TM
G3/8
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design

D4022/1006/T012-TM-6H
G3/8
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design End position detection sensor

D4023/1006/T012-NT
G1/2
CW617N brass
EPDM
0.3 - 16 bar
AC
IP65
normally open Temperature design

D4023/1006/T012-NT
G1/2
CW617N brass
EPDM
0.3 - 16 bar
DC
IP65
normally open Temperature design

D4023/1006/T012-TM
G1/2
CW617N brass
EPDM
0.3 - 20 bar
AC
IP65
normally closed Temperature design

D4023/1006/T012-TM
G1/2
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design

D4023/1006/T012-TM-6H
G1/2
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design End position detection sensor

D4024/1006/T012-NT
G3/4
CW617N brass
EPDM
0.3 - 16 bar
AC
IP65
normally open Temperature design

D4024/1006/T012-NT
G3/4
CW617N brass
EPDM
0.3 - 16 bar
DC
IP65
normally open Temperature design

D4024/1006/T012-TM
G3/4
CW617N brass
EPDM
0.3 - 20 bar
AC
IP65
normally closed Temperature design

D4024/1006/T012-TM
G3/4
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design

D4024/1006/T012-TM-6H
G3/4
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design End position detection sensor

D4025/1006/T012-NT
G1
CW617N brass
EPDM
0.3 - 16 bar
AC
IP65
normally open Temperature design

D4025/1006/T012-NT
G1
CW617N brass
EPDM
0.3 - 16 bar
DC
IP65
normally open Temperature design

D4025/1006/T012-TM
G1
CW617N brass
EPDM
0.3 - 20 bar
AC
IP65
normally closed Temperature design

D4025/1006/T012-TM
G1
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design

D4025/1006/T012-TM-6H
G1
CW617N brass
EPDM
0.3 - 20 bar
DC
IP65
normally closed Temperature design End position detection sensor