Seat Valve electr. direct
Series 3/045
Valve 3/045-69/0815/4272-1W DC
3/2-way change-over valve type 3/045 as a universal valve for distributing and mixing gaseous and liquid media. By closing one of the three ports, the valve can perform a 2/2-way function. Which port is closed depends on whether an NC or NO function is required in the process application. The special feature of this valve design compared to conventional seat valves is that the valve function is guaranteed even when the medium flows through from all directions. The armature chamber is separated from the medium.
For more information follow this link:
Valve 3/045-69/0815/4272-1W DC
Datasheet explicit
Datasheet universal
techn. datasheet - ger/en (PDF) 3/045
Version | 3/045- | |
Type of valve | Seat Valve electr. direct | |
Connection type, valve seat | 69 | G1/2 10mm |
Kv-value (Δp = 1 bar H₂O) | 1.1 m³/h | |
Housing | 08 | AISI 316 Ti - 1.4571(81) |
Sealing | 15 | PEEK/PCTFE-HP |
Voltage type | 4 | DC |
Solenoid power | 27 | 100W |
Protection class | 2 | IP65 |
Valve option | 1W | normally closed + High pressure design for hydrogen |
System pressure | 0 - 200 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, DC | |
Temperature Medium | from -40 °C to 90 °C | |
Temperature Environment | from -27 °C to 40 °C | |
Mounting position | Actuator upright (preferred) or horizontal | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 Solenoid .272 Steel K05127XX | terminal box M16x1,5 | 100% ED | IP65 | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | |
Not applicable
Valve option | 1W | normally closed + High pressure design for hydrogen |
Description | Valve opens with continuous voltage | Anchor with Dynamant-coating | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Customs export | Customs tariff number 84818073; Country of origin Germany; ECCN (US): N; AL: N |