Coaxial Valve electr. direct
Series 2/918-..-10-R270
Valve 2/918-69/1004/.270-IS AC, DC
2/2-way directly controlled axial slide solenoid valve also for highly viscous, lubricating or contaminated media. Type 2/918 valves are preferably used where seat valves cannot be used due to the fluid quality. Another argument in favour of this design is that it can be flowed through and shut off in all directions and can be installed in horizontal and vertical pipelines.
For more information follow this link:
Valve 2/918-69/1004/.270-IS AC, DC
Datasheet explicit
Version | 2/918- | |
Type of valve | Coaxial Valve electr. direct | |
Connection type, valve seat | 69 | G1/2 10mm |
Kv-value (Δp = 1 bar H₂O) | 2.5 m³/h | |
Housing | 10 | CW617N brass | CW617N brass |
Sealing | 04 | PTFE |
Voltage type | -- | To be specified later |
Solenoid power | 27 | 35W |
Protection class | 0 | IP65 |
Valve option | IS | normally closed + IP68 incl. 3m cable + Back pressure safe |
System pressure | 0 - 40 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC | |
Temperature Medium | from -40 °C to 100 °C | |
Temperature Environment | from -40 °C to 50 °C | |
Mounting position | in any position | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 connector FormA EN175301-803/A | max. current 10A | 4x90°| IP65 when installed | connectable cables Ø 5-10 mm max.1.5mm² | 1x solenoid 35W, 100%ED 1 Connector w. rectifier & VDR EN 175301-803 A | IP65 when installed | Connectable cables Ø 4.5-11mm max.1.5mm² | 1x solenoid 41W, 100%ED |
Valve option | IS | normally closed + IP68 incl. 3m cable + Back pressure safe |
Description | Valve opens with continuous voltage | Solenoid encapsulated with 3m cable end | Pressure in both directions | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Customs export | Customs tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N |