Product data sheet
Valve
2-738-25-1004-S242-F-1U,
September 16, 2024
Seat Valve electrically force-controlled
Series 2/738-23-27/1004 CRYO
Valve 2/738-25/1004/.242-F-1U AC, DC

Our classic in the field of cryogenic applications. If you are looking for an absolutely safe valve for shutting off cryogenic fluids down to -196°C, then you have come to the right place. Type 2/738 is a cryogenic valve adapted to the application with high functional safety. If required, the valves can be equipped with limit switches. The valve opens automatically as soon as the downstream pressure is greater than the upstream pressure.

For more information follow this link:
Valve 2/738-25/1004/.242-F-1U AC, DC
Link Icon
Datasheet explicit
Version2/738-
Type of valveSeat Valve electrically force-controlled
Connection type, valve seat25G1 25mm
Kv-value (Δp = 1 bar H₂O)11.3 m³/h
Housing10CW617N brass
Sealing04PTFE
Voltage type--To be specified later
Solenoid power2446W
Protection class2IP65
Valve optionF-1Unormally closed + Reed contact 2-wire RC27-S + free of Oil/grease + dry
System pressure0 - 20 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -196 °C to 80 °C
Temperature Environmentfrom -40 °C to 40 °C
Mounting position
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 Solenoid S242 Steel | humidity protected | Terminal box M16x1,5 | Cable clamping range 5-10mm | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx |
Valve optionF-1Unormally closed + Reed contact 2-wire RC27-S + free of Oil/grease + dry
DescriptionValve opens with continuous voltage | Reed contact | RC27-S Art. B0044.000389 | Contact type: normally open contact | place of install.: top / horizontal | Signal: closed | Connector DIN EN 43650 Form C Art. B0040.000097 | Innerparts dry and specially cleaned
REACH-RoHS conformityREACH Yes | RoHS Yes
Customs exportCustoms tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N