Seat Valve electrically force-controlled
Series 2/738-23-24-25-27/0804 CRYO
Valve 2/738-24/0804/.272-NO-F-6R AC, DC
Our classic in the field of cryogenic applications. If you are looking for an absolutely safe valve for shutting off cryogenic fluids down to -196°C, then you have come to the right place. Type 2/738 is a cryogenic valve adapted to the application with high functional safety. The valve opens automatically as soon as the pressure downstream of the valve is greater than the pressure upstream of the valve.
For more information follow this link:
Valve 2/738-24/0804/.272-NO-F-6R AC, DC
Datasheet explicit
Datasheet universal
datasheet 49MS-LIN 2/738 DN13-40
Instructions
Instructions Solenoid valves, forced-operated
Ventilhub-Einstellung ab Magnet .322/.328 bis .352/.358
Solenoid coil S272
Solenoid coil, Certificates
Techsheet solenoid coil S242
Techsheet solenoid coil S322
Techsheet solenoid coil S272
Others
Turck BIM-PST-AP6X_46240
Sensorkabel M8
Service card sensor, setting instructions
EC Declaration of Conformity
REACH Declaration
RoHS Declaration
Videos
Version | 2/738- | |
Type of valve | Seat Valve electrically force-controlled | |
Connection type, valve seat | 24 | G3/4 20mm |
Kv-value (Δp = 1 bar H₂O) | 9 m³/h | |
Housing | 08 | AISI 316 Ti - 1.4571(81) | AISI 316 Ti - 1.4571(81) |
Sealing | 04 | PTFE |
Voltage type | -- | To be specified later |
Solenoid power | 27 | 100W |
Protection class | 2 | IP65 |
Valve option | NO-F-6R | normally open + free of Oil/grease + dry + Magnetic sensor inductive 3-wire N/O contact PNP |
System pressure | 0 - 40 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC | |
Temperature Medium | from -196 °C to 80 °C | |
Temperature Environment | from -40 °C to 40 °C | |
Mounting position | Pipeline horizontal, Actuator vertical up | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 Solenoid S272 Steel | humidity protected | Terminal box M16x1,5 | Cable clamping range 5-10mm | Valve MatchCode G0xx.xxxxxx.0xx.099.0xx | Rectifier integrated in the coil housing |
Not applicable
Valve option | NO-F-6R | normally open + free of Oil/grease + dry + Magnetic sensor inductive 3-wire N/O contact PNP |
Description | Valve closes with continous voltage | Innerparts dry and specially cleaned | Magnetic field sensor | Turck BIM-PST-AP6X_46240 | place of install.: top | Valve position: OPEN | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Net weight | 5.4 kg | |
Switching time (at 6 bar gas) | On: 120 ms | Off: 160 ms | |
Customs export | Customs tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N |