Seat Valve electrically force-controlled
Series 2/164-FL +300°C GS
Valve 2/164-02/0500/.242-DT-B0 AC, DC
The type 2/164 solenoid valve for high temperature applications up to + 300°C. Special Valve with distance unit between body and actuator. With metallic seat seal.
For more information follow this link:
Valve 2/164-02/0500/.242-DT-B0 AC, DC
Datasheet explicit
Version | 2/164- | |
Type of valve | Seat Valve electrically force-controlled | |
Connection type, valve seat | 02 | DN20 20mm |
Kv-value (Δp = 1 bar H₂O) | 9.8 m³/h | |
Housing | 05 | EN-GP240GH cast steel | EN-GP240GH cast steel |
Sealing | 00 | Metall/Wills® |
Voltage type | -- | To be specified later |
Solenoid power | 24 | 26W |
Protection class | 2 | IP65 |
Valve option | DT-B0 | normally closed + Temperature max. +250°C + Magnetic sensor inductive 3-wire N/O contact PNP |
System pressure | 0 - 12 bar | |
Valve type | 12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC | |
Temperature Medium | from -20 °C to 300 °C | |
Temperature Environment | from -20 °C to 40 °C | |
Mounting position | up to +250°C in any position, above +250°C actuator downwards | |
Specific use case | Closed system (includes open system) | |
scope of delivery | 1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T242 KT05124XX Steel | Terminal box M16x1,5 | 100%ED | Cable clamping range 5 - 10mm | |
Not applicable
Valve option | DT-B0 | normally closed + Temperature max. +250°C + Magnetic sensor inductive 3-wire N/O contact PNP |
Description | Valve opens with continuous voltage | Distance unit between valve body and actuator | Magnetic field sensor | Turck BIM-PST-AP6X_46240 | Cable 2m, 3-wire | place of install.: top | Valve position: OPEN and CLOSE | |
REACH-RoHS conformity | REACH Yes | RoHS Yes | |
Net weight | 10.4 kg | |
Switching time (at 6 bar gas) | On: 100 ms | Off: 140 ms | |
Customs export | Customs tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N |