Product data sheet
Valve
2-164-25-1000-T242-DT-B0,
December 27, 2024
Seat Valve electrically force-controlled
Series 2/164-10-G
Valve 2/164-25/1000/.242-DT-B0 AC, DC

The type 2/164 solenoid valve for high temperature applications up to + 300°C. Special Valve with distance unit between body and actuator. With metallic seat seal.

For more information follow this link:
Valve 2/164-25/1000/.242-DT-B0 AC, DC
Link Icon
Datasheet explicit
Version2/164-
Type of valveSeat Valve electrically force-controlled
Connection type, valve seat25G1 25mm
Kv-value (Δp = 1 bar H₂O)11.5 m³/h
Housing10CW617N brass
Sealing00Metall/Wills®
Voltage type--To be specified later
Solenoid power2426W
Protection class2IP65
Valve optionDT-B0normally closed + Temperature max. +250°C + Magnetic switch 2-fold OPEN and CLOSE inductive 3-wire N/O contact PNP
System pressure0 - 12 bar
Valve type12V, 24V, 48V, 110V, 120V, 220V, 230V, AC, DC
Temperature Mediumfrom -20 °C to 300 °C
Temperature Environmentfrom -40 °C to 40 °C
Mounting positionup to +250°C in any position, above +250°C actuator downwards
Specific use caseClosed system (includes open system)
scope of delivery1 valve, 1 separate rectifier B0046.0000015 | 1 Solenoid T242 KT05124XX Steel | Terminal box M16x1,5 | 100%ED | Cable clamping range 5 - 10mm |
Not applicable
Valve optionDT-B0normally closed + Temperature max. +250°C + Magnetic switch 2-fold OPEN and CLOSE inductive 3-wire N/O contact PNP
DescriptionValve opens with continuous voltage | Distance unit between valve body and actuator | Turck BIM-PST-AP6X_46240 | fixed sensor cable, 2 m, 3-pole | place of install.: top | Valve position: OPEN and CLOSE
REACH-RoHS conformityREACH Yes | RoHS Yes
Net weight6.2 kg
Customs exportCustoms tariff number 84818079; Country of origin Germany; ECCN (US): N; AL: N